Part No. 10053-308
© 2007 JB Industries Inc.
Evacuation, complete with pressure drop test using vacuum
gauge can be performed as well as charging system. Manifold
will hold vacuum of 25 microns or better without leaking.
D10053 Economy
Deep Vacuum Manifold
US. Pat. #3615109
A
B
4
3
2
EVACUATION:
1. Close Valves A and B . Valve A isolates Port #2
from system. Valve B isolates system from pump.
2. Install directly onto intake of your pump via the 3/8”
flare swivel coupler #1. Note: Do not wrench coupler.
Finger tightening will seal this connection for deep
vacuum.
3. If using vacuum gauge install to Port #2 using
O-ring coupler. If vacuum gauge is not used, cap
port.
4. Using deep vacuum flexible metal hoses with O-ring
couplers make connections at Ports #3 and #4 and
to the suction and discharge service valves on the
unit to be evacuated. This allows you to evacuate
from the high and low side of the system. Note: Unit
should be purged of refrigerant prior to connection.
5. Open suction and discharge service valves and
manifold Valve B . Turn on pump and open Valve A if
using micron gauge. Evacuate to manufacturer’s
recommendations and close Valve B . This isolates
the pump from the system to perform pressure drop
test using micron gauge.
TO CHARGE SYSTEM:
1. Close Valve B . This will be closed after pressure
drop test if using vacuum gauge. Remove gauge
connection.
2. Connect refrigerant line to Port #2 . Connection at
port should be loose. Open refrigerant supply. When
air is purged, finger tighten connection at Port #2
and open Valve A to charge system.
1
Technical service: 800-323-0811